EMS Registers
Search the EMS register map to find the address and data type of the register you want to write, then send it to the editor.
Source
The EMS writes its merged register map into a file inside its own container, and the archive the simulator syncs deliberately leaves that ems/ directory out. The EMS serves the file itself at GET /api/v1/ems/register-map, so this page reads it over HTTP like every other EMS fact it shows - there is no copy in the stack's shared volume.
7,404 of 7,404 registers
| Address | Type | Regs | Access | Category | Register | Value | |
|---|---|---|---|---|---|---|---|
| 1 | INT16U | 1 | read/write | ems__control |
ems_operation_mode
ems_operation_mode
23 enum values
|
2 | Use → row 9 |
| 2 | INT16U | 1 | read/write | ems__control |
ems_control_mode
ems_control_mode
3 enum values
|
0 | Use → row 9 |
| 3 | INT16U | 1 | read only | ems__status |
ems_operation_status
ems_operation_status
23 enum values
|
0
unset
|
Use → row 9 |
| 4 | INT16U | 1 | read/write | ems__control |
control_settings__ems_refresh_rate_hz
control_settings › ems_refresh_rate_hz
|
2 | Use → row 9 |
| 5 | INT16U | 1 | read only | ems__status | active_function_count | 4 | Use → row 9 |
| 6 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__enabled
functions › Payload_Diagnostic_Test › enabled
|
1 | Use → row 9 |
| 7 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__test_duration_sec
functions › Payload_Diagnostic_Test › test_duration_sec
|
30 | Use → row 9 |
| 8 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__bess__ffr_fcr_response_test
functions › Payload_Diagnostic_Test › bess › ffr_fcr_response_test
|
1 | Use → row 9 |
| 9 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__bess__active_reactive_power_test
functions › Payload_Diagnostic_Test › bess › active_reactive_power_test
|
1 | Use → row 9 |
| 10 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__bess__capacity_test
functions › Payload_Diagnostic_Test › bess › capacity_test
|
1 | Use → row 9 |
| 11 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__bess__internal_resistance_test
functions › Payload_Diagnostic_Test › bess › internal_resistance_test
|
1 | Use → row 9 |
| 12 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__bess__thermal_response_test
functions › Payload_Diagnostic_Test › bess › thermal_response_test
|
1 | Use → row 9 |
| 13 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__bess__ocv_test
functions › Payload_Diagnostic_Test › bess › ocv_test
|
1 | Use → row 9 |
| 14 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__bess__grid_forming_test
functions › Payload_Diagnostic_Test › bess › grid_forming_test
|
1 | Use → row 9 |
| 15 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__ev_charger__charging_power_current_test
functions › Payload_Diagnostic_Test › ev_charger › charging_power_current_test
|
1 | Use → row 9 |
| 16 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__ev_charger__charging_efficiency_test
functions › Payload_Diagnostic_Test › ev_charger › charging_efficiency_test
|
1 | Use → row 9 |
| 17 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__ev_charger__load_balancing_response_test
functions › Payload_Diagnostic_Test › ev_charger › load_balancing_response_test
|
1 | Use → row 9 |
| 18 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__ev_charger__ramp_rate_test
functions › Payload_Diagnostic_Test › ev_charger › ramp_rate_test
|
1 | Use → row 9 |
| 19 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__ev_charger__interruption_recovery_test
functions › Payload_Diagnostic_Test › ev_charger › interruption_recovery_test
|
1 | Use → row 9 |
| 20 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__ev_charger__energy_measurement_accuracy_test
functions › Payload_Diagnostic_Test › ev_charger › energy_measurement_accuracy_test
|
1 | Use → row 9 |
| 21 | INT16U | 1 | read/write | ems__control |
functions__Payload_Diagnostic_Test__ev_charger__session_performance_test
functions › Payload_Diagnostic_Test › ev_charger › session_performance_test
|
1 | Use → row 9 |
| 22 | INT16U | 1 | read/write | ems__control |
functions__Self_Test__enabled
functions › Self_Test › enabled
|
1 | Use → row 9 |
| 23 | INT16U | 1 | read/write | ems__control |
functions__Self_Test__alarm_diagnostic_test__include_self_test_alarms
functions › Self_Test › alarm_diagnostic_test › include_self_test_alarms
|
1 | Use → row 9 |
| 24 | INT16U | 1 | read/write | ems__control |
functions__Self_Test__alarm_diagnostic_test__appear_timeout_s
functions › Self_Test › alarm_diagnostic_test › appear_timeout_s
|
30 | Use → row 9 |
| 25 | INT16U | 1 | read/write | ems__control |
functions__Self_Test__alarm_diagnostic_test__clear_timeout_s
functions › Self_Test › alarm_diagnostic_test › clear_timeout_s
|
45 | Use → row 9 |
| 26 | INT16U | 1 | read/write | ems__control |
functions__Self_Test__alarm_diagnostic_test__row_settle_s
functions › Self_Test › alarm_diagnostic_test › row_settle_s
|
8 | Use → row 9 |
| 27 | INT16U | 1 | read/write | ems__control |
functions__Self_Test__alarm_diagnostic_test__max_alarms_per_device
functions › Self_Test › alarm_diagnostic_test › max_alarms_per_device
|
0 | Use → row 9 |
| 28 | FLOAT32 | 2 | read/write | ems__control |
functions__Self_Test__alarm_diagnostic_test__simulator_url
functions › Self_Test › alarm_diagnostic_test › simulator_url
|
0
unset
|
Use → row 9 |
| 30 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__enabled
functions › Manual_Operation › enabled
|
1 | Use → row 9 |
| 31 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__power_setpoint_kw
functions › Manual_Operation › power_setpoint_kw
|
40 | Use → row 9 |
| 32 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__ramp_rate_kw_s
functions › Manual_Operation › ramp_rate_kw_s
|
1 | Use → row 9 |
| 33 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__soc_limits__min_soc_pct
functions › Manual_Operation › soc_limits › min_soc_pct
|
10 | Use → row 9 |
| 34 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__soc_limits__max_soc_pct
functions › Manual_Operation › soc_limits › max_soc_pct
|
80 | Use → row 9 |
| 35 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__soc_recovery_target_pct
functions › Manual_Operation › soc_recovery_target_pct
|
12 | Use → row 9 |
| 36 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__power_caps_kw__charge_cap_kw
functions › Manual_Operation › power_caps_kw › charge_cap_kw
|
100 | Use → row 9 |
| 37 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__power_caps_kw__discharge_cap_kw
functions › Manual_Operation › power_caps_kw › discharge_cap_kw
|
70 | Use → row 9 |
| 38 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__telemetry_control__command_confirmation
functions › Manual_Operation › telemetry_control › command_confirmation
|
1 | Use → row 9 |
| 39 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__safety__trip_on_overvoltage
functions › Manual_Operation › safety › trip_on_overvoltage
|
1 | Use → row 9 |
| 40 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__safety__trip_on_undervoltage
functions › Manual_Operation › safety › trip_on_undervoltage
|
1 | Use → row 9 |
| 41 | INT16U | 1 | read/write | ems__control |
functions__Manual_Operation__safety__trip_on_overtemperature
functions › Manual_Operation › safety › trip_on_overtemperature
|
1 | Use → row 9 |
| 42 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__enabled
functions › Arbitrage › enabled
|
0 | Use → row 9 |
| 43 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__tick__interval_seconds
functions › Arbitrage › tick › interval_seconds
|
300 | Use → row 9 |
| 44 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__tick__run_on_start
functions › Arbitrage › tick › run_on_start
|
1 | Use → row 9 |
| 45 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__tick__skip_cycles_log
functions › Arbitrage › tick › skip_cycles_log
|
1 | Use → row 9 |
| 46 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__tick__zero_power_on_skip
functions › Arbitrage › tick › zero_power_on_skip
|
1 | Use → row 9 |
| 47 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__price_source__timeout_ms
functions › Arbitrage › price_source › timeout_ms
|
4000 | Use → row 9 |
| 48 | FLOAT32 | 2 | read/write | ems__control |
functions__Arbitrage__price_source__http__headers
functions › Arbitrage › price_source › http › headers
|
0
unset
|
Use → row 9 |
| 50 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__price_source__resolution_minutes
functions › Arbitrage › price_source › resolution_minutes
|
15 | Use → row 9 |
| 51 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__prefer_next_slot
functions › Arbitrage › strategy › prefer_next_slot
|
1 | Use → row 9 |
| 52 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__min_spread
functions › Arbitrage › strategy › min_spread
|
0 | Use → row 9 |
| 53 | FLOAT32 | 2 | read/write | ems__control |
functions__Arbitrage__strategy__buy_threshold
functions › Arbitrage › strategy › buy_threshold
|
0.1 | Use → row 9 |
| 55 | FLOAT32 | 2 | read/write | ems__control |
functions__Arbitrage__strategy__sell_threshold
functions › Arbitrage › strategy › sell_threshold
|
0.12 | Use → row 9 |
| 57 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__buy_power_kw
functions › Arbitrage › strategy › buy_power_kw
|
20 | Use → row 9 |
| 58 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__sell_power_kw
functions › Arbitrage › strategy › sell_power_kw
|
20 | Use → row 9 |
| 59 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__tomorrow_plan__enabled
functions › Arbitrage › strategy › tomorrow_plan › enabled
|
1 | Use → row 9 |
| 60 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__tomorrow_plan__charge_cheapest_slots
functions › Arbitrage › strategy › tomorrow_plan › charge_cheapest_slots
|
8 | Use → row 9 |
| 61 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__tomorrow_plan__discharge_most_expensive_slots
functions › Arbitrage › strategy › tomorrow_plan › discharge_most_expensive_slots
|
8 | Use → row 9 |
| 62 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__tomorrow_plan__charge_power_kw
functions › Arbitrage › strategy › tomorrow_plan › charge_power_kw
|
20 | Use → row 9 |
| 63 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__strategy__tomorrow_plan__discharge_power_kw
functions › Arbitrage › strategy › tomorrow_plan › discharge_power_kw
|
20 | Use → row 9 |
| 64 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__optional__hysteresis
functions › Arbitrage › optional › hysteresis
|
0 | Use → row 9 |
| 65 | FLOAT32 | 2 | read/write | ems__control |
functions__Arbitrage__optional__conflict_rule
functions › Arbitrage › optional › conflict_rule
|
0
unset
|
Use → row 9 |
| 67 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__optional__hysteresis_kw
functions › Arbitrage › optional › hysteresis_kw
|
0 | Use → row 9 |
| 68 | INT16U | 1 | read/write | ems__control |
functions__Arbitrage__ramp_rate_kw_s
functions › Arbitrage › ramp_rate_kw_s
|
100 | Use → row 9 |
| 69 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__enabled
functions › Peak_Shaving › enabled
|
1 | Use → row 9 |
| 70 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__peak_threshold_kw
functions › Peak_Shaving › peak_threshold_kw
|
50 | Use → row 9 |
| 71 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__discharge_power_limit_kw
functions › Peak_Shaving › discharge_power_limit_kw
|
50 | Use → row 9 |
| 72 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__min_soc_pct
functions › Peak_Shaving › min_soc_pct
|
10 | Use → row 9 |
| 73 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__recovery_soc_pct
functions › Peak_Shaving › recovery_soc_pct
|
67 | Use → row 9 |
| 74 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__response_time_ms
functions › Peak_Shaving › response_time_ms
|
90 | Use → row 9 |
| 75 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__optional__hysteresis_kw
functions › Peak_Shaving › optional › hysteresis_kw
|
2 | Use → row 9 |
| 76 | INT16U | 1 | read/write | ems__control |
functions__Peak_Shaving__ramp_rate_kw_s
functions › Peak_Shaving › ramp_rate_kw_s
|
100 | Use → row 9 |
| 77 | INT16U | 1 | read/write | ems__control |
functions__Valley_Filling__enabled
functions › Valley_Filling › enabled
|
0 | Use → row 9 |
| 78 | INT16U | 1 | read/write | ems__control |
functions__Valley_Filling__valley_threshold_kw
functions › Valley_Filling › valley_threshold_kw
|
75 | Use → row 9 |
| 79 | INT16U | 1 | read/write | ems__control |
functions__Valley_Filling__charge_power_limit_kw
functions › Valley_Filling › charge_power_limit_kw
|
120 | Use → row 9 |
| 80 | FLOAT32 | 2 | read/write | ems__control |
functions__Valley_Filling__max_soc_pct
functions › Valley_Filling › max_soc_pct
|
0
unset
|
Use → row 9 |
| 82 | FLOAT32 | 2 | read/write | ems__control |
functions__Valley_Filling__min_soc_pct
functions › Valley_Filling › min_soc_pct
|
0
unset
|
Use → row 9 |
| 84 | FLOAT32 | 2 | read/write | ems__control |
functions__Valley_Filling__response_time_ms
functions › Valley_Filling › response_time_ms
|
0
unset
|
Use → row 9 |
| 86 | INT16U | 1 | read/write | ems__control |
functions__Valley_Filling__optional__hysteresis_kw
functions › Valley_Filling › optional › hysteresis_kw
|
2 | Use → row 9 |
| 87 | INT16U | 1 | read/write | ems__control |
functions__Valley_Filling__ramp_rate_kw_s
functions › Valley_Filling › ramp_rate_kw_s
|
100 | Use → row 9 |
| 88 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__enabled
functions › Scheduled_Charge_Discharge › enabled
|
0 | Use → row 9 |
| 89 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__soc_limits__min_soc_pct
functions › Scheduled_Charge_Discharge › soc_limits › min_soc_pct
|
10 | Use → row 9 |
| 90 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__soc_limits__max_soc_pct
functions › Scheduled_Charge_Discharge › soc_limits › max_soc_pct
|
80 | Use → row 9 |
| 91 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__power_limits__charge_power_limit_kw
functions › Scheduled_Charge_Discharge › power_limits › charge_power_limit_kw
|
30 | Use → row 9 |
| 92 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__power_limits__discharge_power_limit_kw
functions › Scheduled_Charge_Discharge › power_limits › discharge_power_limit_kw
|
30 | Use → row 9 |
| 93 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__response_time_ms
functions › Scheduled_Charge_Discharge › response_time_ms
|
1 | Use → row 9 |
| 94 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__validation__prevent_overlaps
functions › Scheduled_Charge_Discharge › validation › prevent_overlaps
|
1 | Use → row 9 |
| 95 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__validation__min_duration_minutes
functions › Scheduled_Charge_Discharge › validation › min_duration_minutes
|
5 | Use → row 9 |
| 96 | INT16U | 1 | read/write | ems__control |
functions__Scheduled_Charge_Discharge__ramp_rate_kw_s
functions › Scheduled_Charge_Discharge › ramp_rate_kw_s
|
100 | Use → row 9 |
| 97 | INT16U | 1 | read/write | ems__control |
functions__Backup__enabled
functions › Backup › enabled
|
0 | Use → row 9 |
| 98 | FLOAT32 | 2 | read/write | ems__control |
functions__Backup__backup_power_setpoint_kw
functions › Backup › backup_power_setpoint_kw
|
0
unset
|
Use → row 9 |
| 100 | FLOAT32 | 2 | read/write | ems__control |
functions__Backup__min_soc_pct
functions › Backup › min_soc_pct
|
0
unset
|
Use → row 9 |
| 102 | FLOAT32 | 2 | read/write | ems__control |
functions__Backup__recovery_soc_pct
functions › Backup › recovery_soc_pct
|
0
unset
|
Use → row 9 |
| 104 | FLOAT32 | 2 | read/write | ems__control |
functions__Backup__response_time_ms
functions › Backup › response_time_ms
|
0
unset
|
Use → row 9 |
| 106 | INT16U | 1 | read/write | ems__control |
functions__Backup__black_start_enable
functions › Backup › black_start_enable
|
1 | Use → row 9 |
| 107 | INT16U | 1 | read/write | ems__control |
functions__Backup__grid_mode_switch__enabled
functions › Backup › grid_mode_switch › enabled
|
0 | Use → row 9 |
| 108 | INT16U | 1 | read/write | ems__control |
functions__Backup__grid_mode_switch__grid_loss_voltage_v
functions › Backup › grid_mode_switch › grid_loss_voltage_v
|
100 | Use → row 9 |
| 109 | INT16U | 1 | read/write | ems__control |
functions__Backup__grid_mode_switch__grid_loss_frequency_hz_low
functions › Backup › grid_mode_switch › grid_loss_frequency_hz_low
|
47 | Use → row 9 |
| 110 | INT16U | 1 | read/write | ems__control |
functions__Backup__grid_mode_switch__grid_loss_frequency_hz_high
functions › Backup › grid_mode_switch › grid_loss_frequency_hz_high
|
53 | Use → row 9 |
| 111 | INT16U | 1 | read/write | ems__control |
functions__Backup__grid_mode_switch__switch_delay_s
functions › Backup › grid_mode_switch › switch_delay_s
|
3 | Use → row 9 |
| 112 | INT16U | 1 | read/write | ems__control |
functions__Backup__power_dispatch__enabled
functions › Backup › power_dispatch › enabled
|
0 | Use → row 9 |
Use opens the editor with the address and type filled into its first row. The address shown here is the address on the wire: a register declared at 3020 is read and written with 3020.