The EMS writes its merged register map into a file inside its own container, and the archive the simulator syncs deliberately leaves that ems/ directory out. The EMS serves the file itself at GET /api/v1/ems/register-map, so this page reads it over HTTP like every other EMS fact it shows - there is no copy in the stack's shared volume.

7,404 of 7,404 registers

Address Type Regs Access Category Register Value
26139 UINT16 1 read only bmu8__temperature_sensors cell10_temp_c — Use → row 6
26140 UINT16 1 read only bmu8__temperature_sensors cell11_temp_c — Use → row 6
26141 UINT16 1 read only bmu8__temperature_sensors cell12_temp_c — Use → row 6
26142 UINT16 1 read only bmu8__temperature_sensors cell13_temp_c — Use → row 6
26143 UINT16 1 read only bmu8__temperature_sensors cell14_temp_c — Use → row 6
26144 UINT16 1 read only bmu8__temperature_sensors cell15_temp_c — Use → row 6
26145 UINT16 1 read only bmu8__temperature_sensors cell16_temp_c — Use → row 6
26146 UINT16 1 read only bmu8__temperature_sensors cell17_temp_c — Use → row 6
26147 UINT16 1 read only bmu8__temperature_sensors cell18_temp_c — Use → row 6
26148 UINT16 1 read only bmu8__temperature_sensors cell19_temp_c — Use → row 6
26149 UINT16 1 read only bmu8__temperature_sensors cell20_temp_c — Use → row 6
26150 UINT16 1 read only bmu8__temperature_sensors cell21_temp_c — Use → row 6
26151 UINT16 1 read only bmu8__temperature_sensors cell22_temp_c — Use → row 6
26152 UINT16 1 read only bmu8__temperature_sensors cell23_temp_c — Use → row 6
26153 UINT16 1 read only bmu8__temperature_sensors cell24_temp_c — Use → row 6
26154 UINT16 1 read only bmu8__status soc — Use → row 6
26155 UINT16 1 read only bmu8__status soh — Use → row 6
26156 BOOL 1 read only bmu8__alarms pack_general_alarm — Use → row 6
26157 BOOL 1 read only bmu8__alarms cell_overvoltage_alarm — Use → row 6
26158 BOOL 1 read only bmu8__alarms cell_undervoltage_alarm — Use → row 6
26159 BOOL 1 read only bmu8__alarms temperature_over_alarm — Use → row 6
26160 BOOL 1 read only bmu8__alarms temperature_under_alarm — Use → row 6
26161 BOOL 1 read only bmu8__alarms communication_fault — Use → row 6
26162 UINT16 1 read/write bmu8__control__writeable_thresholds cell_overvoltage_threshold — Use → row 6
26163 UINT16 1 read/write bmu8__control__writeable_thresholds cell_undervoltage_threshold — Use → row 6
26164 UINT16 1 read/write bmu8__control__writeable_thresholds temperature_over_threshold — Use → row 6
26165 UINT16 1 read/write bmu8__control__writeable_thresholds temperature_under_threshold — Use → row 6
26166 UINT16 1 read/write bmu8__control__writeable_thresholds charge_current_limit — Use → row 6
26167 UINT16 1 read/write bmu8__control__writeable_thresholds discharge_current_limit — Use → row 6
26168 UINT16 1 read only bmu9__cell_voltage cell1_voltage_v — Use → row 6
26169 UINT16 1 read only bmu9__cell_voltage cell2_voltage_v — Use → row 6
26170 UINT16 1 read only bmu9__cell_voltage cell3_voltage_v — Use → row 6
26171 UINT16 1 read only bmu9__cell_voltage cell4_voltage_v — Use → row 6
26172 UINT16 1 read only bmu9__cell_voltage cell5_voltage_v — Use → row 6
26173 UINT16 1 read only bmu9__cell_voltage cell6_voltage_v — Use → row 6
26174 UINT16 1 read only bmu9__cell_voltage cell7_voltage_v — Use → row 6
26175 UINT16 1 read only bmu9__cell_voltage cell8_voltage_v — Use → row 6
26176 UINT16 1 read only bmu9__cell_voltage cell9_voltage_v — Use → row 6
26177 UINT16 1 read only bmu9__cell_voltage cell10_voltage_v — Use → row 6
26178 UINT16 1 read only bmu9__cell_voltage cell11_voltage_v — Use → row 6
26179 UINT16 1 read only bmu9__cell_voltage cell12_voltage_v — Use → row 6
26180 UINT16 1 read only bmu9__cell_voltage cell13_voltage_v — Use → row 6
26181 UINT16 1 read only bmu9__cell_voltage cell14_voltage_v — Use → row 6
26182 UINT16 1 read only bmu9__cell_voltage cell15_voltage_v — Use → row 6
26183 UINT16 1 read only bmu9__cell_voltage cell16_voltage_v — Use → row 6
26184 UINT16 1 read only bmu9__cell_voltage cell17_voltage_v — Use → row 6
26185 UINT16 1 read only bmu9__cell_voltage cell18_voltage_v — Use → row 6
26186 UINT16 1 read only bmu9__cell_voltage cell19_voltage_v — Use → row 6
26187 UINT16 1 read only bmu9__cell_voltage cell20_voltage_v — Use → row 6
26188 UINT16 1 read only bmu9__cell_voltage cell21_voltage_v — Use → row 6
26189 UINT16 1 read only bmu9__cell_voltage cell22_voltage_v — Use → row 6
26190 UINT16 1 read only bmu9__cell_voltage cell23_voltage_v — Use → row 6
26191 UINT16 1 read only bmu9__cell_voltage cell24_voltage_v — Use → row 6
26192 UINT16 1 read only bmu9__temperature_sensors cell1_temp_c — Use → row 6
26193 UINT16 1 read only bmu9__temperature_sensors cell2_temp_c — Use → row 6
26194 UINT16 1 read only bmu9__temperature_sensors cell3_temp_c — Use → row 6
26195 UINT16 1 read only bmu9__temperature_sensors cell4_temp_c — Use → row 6
26196 UINT16 1 read only bmu9__temperature_sensors cell5_temp_c — Use → row 6
26197 UINT16 1 read only bmu9__temperature_sensors cell6_temp_c — Use → row 6
26198 UINT16 1 read only bmu9__temperature_sensors cell7_temp_c — Use → row 6
26199 UINT16 1 read only bmu9__temperature_sensors cell8_temp_c — Use → row 6
26200 UINT16 1 read only bmu9__temperature_sensors cell9_temp_c — Use → row 6
26201 UINT16 1 read only bmu9__temperature_sensors cell10_temp_c — Use → row 6
26202 UINT16 1 read only bmu9__temperature_sensors cell11_temp_c — Use → row 6
26203 UINT16 1 read only bmu9__temperature_sensors cell12_temp_c — Use → row 6
26204 UINT16 1 read only bmu9__temperature_sensors cell13_temp_c — Use → row 6
26205 UINT16 1 read only bmu9__temperature_sensors cell14_temp_c — Use → row 6
26206 UINT16 1 read only bmu9__temperature_sensors cell15_temp_c — Use → row 6
26207 UINT16 1 read only bmu9__temperature_sensors cell16_temp_c — Use → row 6
26208 UINT16 1 read only bmu9__temperature_sensors cell17_temp_c — Use → row 6
26209 UINT16 1 read only bmu9__temperature_sensors cell18_temp_c — Use → row 6
26210 UINT16 1 read only bmu9__temperature_sensors cell19_temp_c — Use → row 6
26211 UINT16 1 read only bmu9__temperature_sensors cell20_temp_c — Use → row 6
26212 UINT16 1 read only bmu9__temperature_sensors cell21_temp_c — Use → row 6
26213 UINT16 1 read only bmu9__temperature_sensors cell22_temp_c — Use → row 6
26214 UINT16 1 read only bmu9__temperature_sensors cell23_temp_c — Use → row 6
26215 UINT16 1 read only bmu9__temperature_sensors cell24_temp_c — Use → row 6
26216 UINT16 1 read only bmu9__status soc — Use → row 6
26217 UINT16 1 read only bmu9__status soh — Use → row 6
26218 BOOL 1 read only bmu9__alarms pack_general_alarm — Use → row 6
26219 BOOL 1 read only bmu9__alarms cell_overvoltage_alarm — Use → row 6
26220 BOOL 1 read only bmu9__alarms cell_undervoltage_alarm — Use → row 6
26221 BOOL 1 read only bmu9__alarms temperature_over_alarm — Use → row 6
26222 BOOL 1 read only bmu9__alarms temperature_under_alarm — Use → row 6
26223 BOOL 1 read only bmu9__alarms communication_fault — Use → row 6
26224 UINT16 1 read/write bmu9__control__writeable_thresholds cell_overvoltage_threshold — Use → row 6
26225 UINT16 1 read/write bmu9__control__writeable_thresholds cell_undervoltage_threshold — Use → row 6
26226 UINT16 1 read/write bmu9__control__writeable_thresholds temperature_over_threshold — Use → row 6
26227 UINT16 1 read/write bmu9__control__writeable_thresholds temperature_under_threshold — Use → row 6
26228 UINT16 1 read/write bmu9__control__writeable_thresholds charge_current_limit — Use → row 6
26229 UINT16 1 read/write bmu9__control__writeable_thresholds discharge_current_limit — Use → row 6
26230 BOOL16 1 read only door_sensor1__doors door_sensor_1_status — Use → row 6
26231 BOOL16 1 read only door_sensor1__doors door_sensor_2_status — Use → row 6
26232 BOOL16 1 read only door_sensor1__doors door_sensor_3_status — Use → row 6
26233 BOOL16 1 read only door_sensor1__doors door_sensor_4_status — Use → row 6
26234 BOOL16 1 read only door_sensor1__doors door_sensor_5_status — Use → row 6
26235 BOOL16 1 read only door_sensor1__doors door_sensor_6_status — Use → row 6
26236 BOOL16 1 read only door_sensor1__doors door_sensor_7_status — Use → row 6
26237 BOOL16 1 read only door_sensor1__doors door_sensor_8_status — Use → row 6
26238 BOOL16 1 read only door_sensor1__doors door_sensor_9_status — Use → row 6