EMS Registers

Search the EMS register map to find the address and data type of the register you want to write, then send it to the editor.

Source

Re-reads the register map from the EMS.
Endpoint: http://ems-backend:8080/api/v1/ems/register-map
Fetched: 2026-11-19T02:09:06+00:00 (from cache)
Size: 2,146,663 bytes · sha256 384a96937d89

The EMS writes its merged register map into a file inside its own container, and the archive the simulator syncs deliberately leaves that ems/ directory out. The EMS serves the file itself at GET /api/v1/ems/register-map, so this page reads it over HTTP like every other EMS fact it shows - there is no copy in the stack's shared volume.

7,404 of 7,404 registers

Address Type Regs Access Category Register Value
26686 FLOAT32 2 read only grid_meter3__currents current_l1_a 0 Use → row 8
26688 FLOAT32 2 read only grid_meter3__currents current_l2_a 0 Use → row 8
26690 FLOAT32 2 read only grid_meter3__currents current_l3_a 0 Use → row 8
26692 FLOAT32 2 read only grid_meter3__currents current_avg_a 0 Use → row 8
26694 FLOAT32 2 read only grid_meter3__currents current_neutral_a 0 Use → row 8
26696 FLOAT32 2 read only grid_meter3__voltages voltage_l1_n_v 0 Use → row 8
26698 FLOAT32 2 read only grid_meter3__voltages voltage_l2_n_v 0 Use → row 8
26700 FLOAT32 2 read only grid_meter3__voltages voltage_l3_n_v 0 Use → row 8
26702 FLOAT32 2 read only grid_meter3__voltages voltage_l1_l2_v 0 Use → row 8
26704 FLOAT32 2 read only grid_meter3__voltages voltage_l2_l3_v 0 Use → row 8
26706 FLOAT32 2 read only grid_meter3__voltages voltage_l3_l1_v 0 Use → row 8
26708 FLOAT32 2 read only grid_meter3__power active_power_total_kw 150 Use → row 8
26710 FLOAT32 2 read only grid_meter3__power reactive_power_total_kvar 0 Use → row 8
26712 FLOAT32 2 read only grid_meter3__power apparent_power_total_kva 0 Use → row 8
26714 FLOAT32 2 read only grid_meter3__power_factor pf_total 1 Use → row 8
26716 FLOAT32 2 read only grid_meter3__frequency frequency_hz 50 Use → row 8
26718 UINT32 2 read only grid_meter3__energies active_energy_import_kwh 0 Use → row 8
26720 UINT32 2 read only grid_meter3__energies active_energy_export_kwh 0 Use → row 8
26722 UINT32 2 read only grid_meter3__energies reactive_energy_import_kvarh 0 Use → row 8
26724 UINT32 2 read only grid_meter3__energies apparent_energy_total_kvah 0 Use → row 8
26726 FLOAT32 2 read only grid_meter4__currents current_l1_a 0 Use → row 8
26728 FLOAT32 2 read only grid_meter4__currents current_l2_a 0 Use → row 8
26730 FLOAT32 2 read only grid_meter4__currents current_l3_a 0 Use → row 8
26732 FLOAT32 2 read only grid_meter4__currents current_avg_a 0 Use → row 8
26734 FLOAT32 2 read only grid_meter4__currents current_neutral_a 0 Use → row 8
26736 FLOAT32 2 read only grid_meter4__voltages voltage_l1_n_v 0 Use → row 8
26738 FLOAT32 2 read only grid_meter4__voltages voltage_l2_n_v 0 Use → row 8
26740 FLOAT32 2 read only grid_meter4__voltages voltage_l3_n_v 0 Use → row 8
26742 FLOAT32 2 read only grid_meter4__voltages voltage_l1_l2_v 0 Use → row 8
26744 FLOAT32 2 read only grid_meter4__voltages voltage_l2_l3_v 0 Use → row 8
26746 FLOAT32 2 read only grid_meter4__voltages voltage_l3_l1_v 0 Use → row 8
26748 FLOAT32 2 read only grid_meter4__power active_power_total_kw 150 Use → row 8
26750 FLOAT32 2 read only grid_meter4__power reactive_power_total_kvar 0 Use → row 8
26752 FLOAT32 2 read only grid_meter4__power apparent_power_total_kva 0 Use → row 8
26754 FLOAT32 2 read only grid_meter4__power_factor pf_total 1 Use → row 8
26756 FLOAT32 2 read only grid_meter4__frequency frequency_hz 50 Use → row 8
26758 UINT32 2 read only grid_meter4__energies active_energy_import_kwh 0 Use → row 8
26760 UINT32 2 read only grid_meter4__energies active_energy_export_kwh 0 Use → row 8
26762 UINT32 2 read only grid_meter4__energies reactive_energy_import_kvarh 0 Use → row 8
26764 UINT32 2 read only grid_meter4__energies apparent_energy_total_kvah 0 Use → row 8
26766 FLOAT32 2 read only grid_meter5__currents current_l1_a 0 Use → row 8
26768 FLOAT32 2 read only grid_meter5__currents current_l2_a 0 Use → row 8
26770 FLOAT32 2 read only grid_meter5__currents current_l3_a 0 Use → row 8
26772 FLOAT32 2 read only grid_meter5__currents current_avg_a 0 Use → row 8
26774 FLOAT32 2 read only grid_meter5__currents current_neutral_a 0 Use → row 8
26776 FLOAT32 2 read only grid_meter5__voltages voltage_l1_n_v 0 Use → row 8
26778 FLOAT32 2 read only grid_meter5__voltages voltage_l2_n_v 0 Use → row 8
26780 FLOAT32 2 read only grid_meter5__voltages voltage_l3_n_v 0 Use → row 8
26782 FLOAT32 2 read only grid_meter5__voltages voltage_l1_l2_v 0 Use → row 8
26784 FLOAT32 2 read only grid_meter5__voltages voltage_l2_l3_v 0 Use → row 8
26786 FLOAT32 2 read only grid_meter5__voltages voltage_l3_l1_v 0 Use → row 8
26788 FLOAT32 2 read only grid_meter5__power active_power_total_kw 150 Use → row 8
26790 FLOAT32 2 read only grid_meter5__power reactive_power_total_kvar 0 Use → row 8
26792 FLOAT32 2 read only grid_meter5__power apparent_power_total_kva 0 Use → row 8
26794 FLOAT32 2 read only grid_meter5__power_factor pf_total 1 Use → row 8
26796 FLOAT32 2 read only grid_meter5__frequency frequency_hz 50 Use → row 8
26798 UINT32 2 read only grid_meter5__energies active_energy_import_kwh 0 Use → row 8
26800 UINT32 2 read only grid_meter5__energies active_energy_export_kwh 0 Use → row 8
26802 UINT32 2 read only grid_meter5__energies reactive_energy_import_kvarh 0 Use → row 8
26804 UINT32 2 read only grid_meter5__energies apparent_energy_total_kvah 0 Use → row 8
26806 FLOAT32 2 read only grid_meter6__currents current_l1_a 0 Use → row 8
26808 FLOAT32 2 read only grid_meter6__currents current_l2_a 0 Use → row 8
26810 FLOAT32 2 read only grid_meter6__currents current_l3_a 0 Use → row 8
26812 FLOAT32 2 read only grid_meter6__currents current_avg_a 0 Use → row 8
26814 FLOAT32 2 read only grid_meter6__currents current_neutral_a 0 Use → row 8
26816 FLOAT32 2 read only grid_meter6__voltages voltage_l1_n_v 0 Use → row 8
26818 FLOAT32 2 read only grid_meter6__voltages voltage_l2_n_v 0 Use → row 8
26820 FLOAT32 2 read only grid_meter6__voltages voltage_l3_n_v 0 Use → row 8
26822 FLOAT32 2 read only grid_meter6__voltages voltage_l1_l2_v 0 Use → row 8
26824 FLOAT32 2 read only grid_meter6__voltages voltage_l2_l3_v 0 Use → row 8
26826 FLOAT32 2 read only grid_meter6__voltages voltage_l3_l1_v 0 Use → row 8
26828 FLOAT32 2 read only grid_meter6__power active_power_total_kw 150 Use → row 8
26830 FLOAT32 2 read only grid_meter6__power reactive_power_total_kvar 0 Use → row 8
26832 FLOAT32 2 read only grid_meter6__power apparent_power_total_kva 0 Use → row 8
26834 FLOAT32 2 read only grid_meter6__power_factor pf_total 1 Use → row 8
26836 FLOAT32 2 read only grid_meter6__frequency frequency_hz 50 Use → row 8
26838 UINT32 2 read only grid_meter6__energies active_energy_import_kwh 0 Use → row 8
26840 UINT32 2 read only grid_meter6__energies active_energy_export_kwh 0 Use → row 8
26842 UINT32 2 read only grid_meter6__energies reactive_energy_import_kvarh 0 Use → row 8
26844 UINT32 2 read only grid_meter6__energies apparent_energy_total_kvah 0 Use → row 8
26846 FLOAT32 2 read only grid_meter7__currents current_l1_a 0 Use → row 8
26848 FLOAT32 2 read only grid_meter7__currents current_l2_a 0 Use → row 8
26850 FLOAT32 2 read only grid_meter7__currents current_l3_a 0 Use → row 8
26852 FLOAT32 2 read only grid_meter7__currents current_avg_a 0 Use → row 8
26854 FLOAT32 2 read only grid_meter7__currents current_neutral_a 0 Use → row 8
26856 FLOAT32 2 read only grid_meter7__voltages voltage_l1_n_v 0 Use → row 8
26858 FLOAT32 2 read only grid_meter7__voltages voltage_l2_n_v 0 Use → row 8
26860 FLOAT32 2 read only grid_meter7__voltages voltage_l3_n_v 0 Use → row 8
26862 FLOAT32 2 read only grid_meter7__voltages voltage_l1_l2_v 0 Use → row 8
26864 FLOAT32 2 read only grid_meter7__voltages voltage_l2_l3_v 0 Use → row 8
26866 FLOAT32 2 read only grid_meter7__voltages voltage_l3_l1_v 0 Use → row 8
26868 FLOAT32 2 read only grid_meter7__power active_power_total_kw 150 Use → row 8
26870 FLOAT32 2 read only grid_meter7__power reactive_power_total_kvar 0 Use → row 8
26872 FLOAT32 2 read only grid_meter7__power apparent_power_total_kva 0 Use → row 8
26874 FLOAT32 2 read only grid_meter7__power_factor pf_total 1 Use → row 8
26876 FLOAT32 2 read only grid_meter7__frequency frequency_hz 50 Use → row 8
26878 UINT32 2 read only grid_meter7__energies active_energy_import_kwh 0 Use → row 8
26880 UINT32 2 read only grid_meter7__energies active_energy_export_kwh 0 Use → row 8
26882 UINT32 2 read only grid_meter7__energies reactive_energy_import_kvarh 0 Use → row 8
26884 UINT32 2 read only grid_meter7__energies apparent_energy_total_kvah 0 Use → row 8
← Previous Page 18 of 75 Next →

Use opens the editor with the address and type filled into its first row. The address shown here is the address on the wire: a register declared at 3020 is read and written with 3020.