EMS Registers

Search the EMS register map to find the address and data type of the register you want to write, then send it to the editor.

Source

Re-reads the register map from the EMS.
Endpoint: http://ems-backend:8080/api/v1/ems/register-map
Fetched: 2026-11-19T03:55:41+00:00 (from cache)
Size: 2,146,664 bytes · sha256 4a8db4d82fbe

The EMS writes its merged register map into a file inside its own container, and the archive the simulator syncs deliberately leaves that ems/ directory out. The EMS serves the file itself at GET /api/v1/ems/register-map, so this page reads it over HTTP like every other EMS fact it shows - there is no copy in the stack's shared volume.

7,404 of 7,404 registers

Address Type Regs Access Category Register Value
27979 BOOL 1 read only pcs11__pcs grid_current_unbalance 0 Use → row 10
27980 BOOL 1 read only pcs11__pcs grid_phase_loss 0 Use → row 10
27981 BOOL 1 read only pcs11__bc_switch_quantities n_line_overcurrent 0 Use → row 10
27982 BOOL 1 read only pcs11__pcs neutral_line_overcurrent 0 Use → row 10
27983 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_busbar_overvoltage 0 Use → row 10
27984 BOOL 1 read only pcs11__pcs pre_charge_bus_overvoltage 0 Use → row 10
27985 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_busbar_undervoltage 0 Use → row 10
27986 BOOL 1 read only pcs11__pcs pre_charge_bus_undervoltage 0 Use → row 10
27987 BOOL 1 read only pcs11__bc_switch_quantities uncontrolled_rectification_busbar_overvoltage 0 Use → row 10
27988 BOOL 1 read only pcs11__pcs uncontrolled_rectifier_bus_overvoltage 0 Use → row 10
27989 BOOL 1 read only pcs11__bc_switch_quantities uncontrolled_rectification_busbar_undervoltage 0 Use → row 10
27990 BOOL 1 read only pcs11__pcs uncontrolled_rectifier_bus_undervoltage 0 Use → row 10
27991 BOOL 1 read only pcs11__bc_switch_quantities running_busbar_overvoltage 0 Use → row 10
27992 BOOL 1 read only pcs11__pcs operating_bus_overvoltage 0 Use → row 10
27993 BOOL 1 read only pcs11__bc_switch_quantities running_busbar_undervoltage 0 Use → row 10
27994 BOOL 1 read only pcs11__pcs operating_bus_undervoltage 0 Use → row 10
27995 BOOL 1 read only pcs11__bc_switch_quantities positive_negative_busbar_imbalance 0 Use → row 10
27996 BOOL 1 read only pcs11__pcs positive_and_negative_bus_unbalance 0 Use → row 10
27997 BOOL 1 read only pcs11__pcs battery_undervoltage 0 Use → row 10
27998 BOOL 1 read only pcs11__bc_switch_quantities current_mode_busbar_undervoltage 0 Use → row 10
27999 BOOL 1 read only pcs11__pcs current_mode_bus_undervoltage 0 Use → row 10
28000 BOOL 1 read only pcs11__pcs battery_overvoltage 0 Use → row 10
28001 BOOL 1 read only pcs11__pcs dc_pre_charge_overcurrent 0 Use → row 10
28002 BOOL 1 read only pcs11__pcs dc_overcurrent 0 Use → row 10
28003 BOOL 1 read only pcs11__pcs balancing_module_software_overcurrent 0 Use → row 10
28004 BOOL 1 read only pcs11__pcs battery_reverse_connection 0 Use → row 10
28005 BOOL 1 read only pcs11__pcs pre_charge_timeout 0 Use → row 10
28006 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_a_phase_overcurrent 0 Use → row 10
28007 BOOL 1 read only pcs11__pcs pre_charge_phase_a_overcurrent 0 Use → row 10
28008 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_b_phase_overcurrent 0 Use → row 10
28009 BOOL 1 read only pcs11__pcs pre_charge_phase_b_overcurrent 0 Use → row 10
28010 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_c_phase_overcurrent 0 Use → row 10
28011 BOOL 1 read only pcs11__pcs pre_charge_phase_c_overcurrent 0 Use → row 10
28012 BOOL 1 read only pcs11__pcs ad_sampling_zero_drift_fault 0 Use → row 10
28013 BOOL 1 read only pcs11__pcs bms_battery_system_fault 0 Use → row 10
28014 BOOL 1 read only pcs11__pcs sts_communication_fault 0 Use → row 10
28015 BOOL 1 read only pcs11__pcs bms_communication_fault 0 Use → row 10
28016 BOOL 1 read only pcs11__pcs slave_module_can_communication_fault 0 Use → row 10
28017 BOOL 1 read only pcs11__pcs ems_communication_fault 0 Use → row 10
28018 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_relay_closure_failure 0 Use → row 10
28019 BOOL 1 read only pcs11__pcs pre_charge_relay_closing_failure 0 Use → row 10
28020 BOOL 1 read only pcs11__pcs pre_charge_relay_opening_failure 0 Use → row 10
28021 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_relay_closure_status_error 0 Use → row 10
28022 BOOL 1 read only pcs11__pcs pre_charge_relay_closing_state_error 0 Use → row 10
28023 BOOL 1 read only pcs11__bc_switch_quantities pre_charge_relay_opening_status_error 0 Use → row 10
28024 BOOL 1 read only pcs11__pcs pre_charge_relay_opening_state_error 0 Use → row 10
28025 BOOL 1 read only pcs11__bc_switch_quantities main_relay_closure_failure 0 Use → row 10
28026 BOOL 1 read only pcs11__pcs main_relay_closing_failure 0 Use → row 10
28027 BOOL 1 read only pcs11__pcs main_relay_opening_failure 0 Use → row 10
28028 BOOL 1 read only pcs11__bc_switch_quantities main_relay_closure_status_error 0 Use → row 10
28029 BOOL 1 read only pcs11__pcs main_relay_closing_state_error 0 Use → row 10
28030 BOOL 1 read only pcs11__bc_switch_quantities main_relay_opening_status_error 0 Use → row 10
28031 BOOL 1 read only pcs11__pcs main_relay_opening_state_error 0 Use → row 10
28032 BOOL 1 read only pcs11__bc_switch_quantities ac_main_relay_adhesion_fault 0 Use → row 10
28033 BOOL 1 read only pcs11__pcs ac_main_relay_welding_fault 0 Use → row 10
28034 BOOL 1 read only pcs11__pcs dc_relay_open_circuit_fault 0 Use → row 10
28035 BOOL 1 read only pcs11__bc_switch_quantities inverter_voltage_a_phase_overvoltage_fault_flag 0 Use → row 10
28036 BOOL 1 read only pcs11__pcs inverter_voltage_phase_a_overvoltage_fault_flag 0 Use → row 10
28037 BOOL 1 read only pcs11__bc_switch_quantities inverter_voltage_b_phase_overvoltage_fault_flag 0 Use → row 10
28038 BOOL 1 read only pcs11__pcs inverter_voltage_phase_b_overvoltage_fault_flag 0 Use → row 10
28039 BOOL 1 read only pcs11__bc_switch_quantities inverter_voltage_c_phase_overvoltage_fault_flag 0 Use → row 10
28040 BOOL 1 read only pcs11__pcs inverter_voltage_phase_c_overvoltage_fault_flag 0 Use → row 10
28041 BOOL 1 read only pcs11__pcs grid_islanding_fault_flag 0 Use → row 10
28042 BOOL 1 read only pcs11__pcs system_resonance_fault_flag 0 Use → row 10
28043 BOOL 1 read only pcs11__bc_switch_quantities software_overvoltage_overcurrent_flag 0 Use → row 10
28044 BOOL 1 read only pcs11__pcs software_overvoltage_and_overcurrent_flag 0 Use → row 10
28045 BOOL 1 read only pcs11__bc_switch_quantities high_voltage_ride_through_timeout_fault_flag 0 Use → row 10
28046 BOOL 1 read only pcs11__pcs high_voltage_ride_through_timeout_fault_flag 0 Use → row 10
28047 BOOL 1 read only pcs11__bc_switch_quantities inverter_voltage_a_phase_undervoltage_fault_flag 0 Use → row 10
28048 BOOL 1 read only pcs11__pcs inverter_voltage_phase_a_undervoltage_fault_flag 0 Use → row 10
28049 BOOL 1 read only pcs11__bc_switch_quantities inverter_voltage_b_phase_undervoltage_fault_flag 0 Use → row 10
28050 BOOL 1 read only pcs11__pcs inverter_voltage_phase_b_undervoltage_fault_flag 0 Use → row 10
28051 BOOL 1 read only pcs11__bc_switch_quantities inverter_voltage_c_phase_undervoltage_fault_flag 0 Use → row 10
28052 BOOL 1 read only pcs11__pcs inverter_voltage_phase_c_undervoltage_fault_flag 0 Use → row 10
28053 BOOL 1 read only pcs11__pcs off_grid_no_synchronization_signal_fault_flag 0 Use → row 10
28054 BOOL 1 read only pcs11__pcs off_grid_short_circuit_fault_flag 0 Use → row 10
28055 BOOL 1 read only pcs11__bc_switch_quantities low_voltage_ride_through_timeout_fault_flag 0 Use → row 10
28056 BOOL 1 read only pcs11__pcs low_voltage_ride_through_timeout_fault_flag 0 Use → row 10
28057 FLOAT32 2 read only pcs11__bc_battery_cluster battery_temperature_c 25 Use → row 10
28059 INT16 1 read only pcs11__bc_battery_cluster dc_current_a 0 Use → row 10
28060 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_1_mv 3300 Use → row 10
28061 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_2_mv 3301 Use → row 10
28062 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_3_mv 3302 Use → row 10
28063 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_4_mv 3303 Use → row 10
28064 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_5_mv 3304 Use → row 10
28065 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_6_mv 3305 Use → row 10
28066 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_7_mv 3306 Use → row 10
28067 UINT16 1 read only pcs11__bc_battery_cluster cell_voltage_8_mv 3307 Use → row 10
28068 UINT16 1 read only pcs11__bc_battery_cluster operating_status 0 Use → row 10
28069 UINT16 1 read only pcs11__bc_battery_cluster cluster_voltage_v 0 Use → row 10
28070 INT16 1 read only pcs11__bc_battery_cluster cluster_current_a 0 Use → row 10
28071 UINT16 1 read only pcs11__bc_battery_cluster maximum_allowable_charging_power_kw 0 Use → row 10
28072 UINT16 1 read only pcs11__bc_battery_cluster maximum_allowable_discharging_power_kw 0 Use → row 10
28073 UINT16 1 read only pcs11__bc_battery_cluster soc_state_of_charge_item 0 Use → row 10
28074 UINT16 1 read only pcs11__bc_battery_cluster soh_state_of_health_item 0 Use → row 10
28075 UINT16 1 read only pcs11__bc_battery_cluster maximum_cell_voltage_mv 0 Use → row 10
28076 UINT16 1 read only pcs11__bc_battery_cluster maximum_cell_voltage_module_number 0 Use → row 10
28077 UINT16 1 read only pcs11__bc_battery_cluster maximum_cell_voltage_cell_number 0 Use → row 10
28078 UINT16 1 read only pcs11__bc_battery_cluster minimum_cell_voltage_mv 0 Use → row 10
28079 UINT16 1 read only pcs11__bc_battery_cluster minimum_cell_voltage_module_number 0 Use → row 10
← Previous Page 29 of 75 Next →

Use opens the editor with the address and type filled into its first row. The address shown here is the address on the wire: a register declared at 3020 is read and written with 3020.