EMS Registers

Search the EMS register map to find the address and data type of the register you want to write, then send it to the editor.

Source

Re-reads the register map from the EMS.
Endpoint: http://ems-backend:8080/api/v1/ems/register-map
Fetched: 2026-11-19T06:48:22+00:00 (from cache)
Size: 2,146,663 bytes · sha256 d7aadbae0d7d

The EMS writes its merged register map into a file inside its own container, and the archive the simulator syncs deliberately leaves that ems/ directory out. The EMS serves the file itself at GET /api/v1/ems/register-map, so this page reads it over HTTP like every other EMS fact it shows - there is no copy in the stack's shared volume.

7,404 of 7,404 registers

Address Type Regs Access Category Register Value
29954 BOOL 1 read only pcs5__pcs pre_charge_relay_closing_failure 0 Use → row 6
29955 BOOL 1 read only pcs5__pcs pre_charge_relay_opening_failure 0 Use → row 6
29956 BOOL 1 read only pcs5__bc_switch_quantities pre_charge_relay_closure_status_error 0 Use → row 6
29957 BOOL 1 read only pcs5__pcs pre_charge_relay_closing_state_error 0 Use → row 6
29958 BOOL 1 read only pcs5__bc_switch_quantities pre_charge_relay_opening_status_error 0 Use → row 6
29959 BOOL 1 read only pcs5__pcs pre_charge_relay_opening_state_error 0 Use → row 6
29960 BOOL 1 read only pcs5__bc_switch_quantities main_relay_closure_failure 0 Use → row 6
29961 BOOL 1 read only pcs5__pcs main_relay_closing_failure 0 Use → row 6
29962 BOOL 1 read only pcs5__pcs main_relay_opening_failure 0 Use → row 6
29963 BOOL 1 read only pcs5__bc_switch_quantities main_relay_closure_status_error 0 Use → row 6
29964 BOOL 1 read only pcs5__pcs main_relay_closing_state_error 0 Use → row 6
29965 BOOL 1 read only pcs5__bc_switch_quantities main_relay_opening_status_error 0 Use → row 6
29966 BOOL 1 read only pcs5__pcs main_relay_opening_state_error 0 Use → row 6
29967 BOOL 1 read only pcs5__bc_switch_quantities ac_main_relay_adhesion_fault 0 Use → row 6
29968 BOOL 1 read only pcs5__pcs ac_main_relay_welding_fault 0 Use → row 6
29969 BOOL 1 read only pcs5__pcs dc_relay_open_circuit_fault 0 Use → row 6
29970 BOOL 1 read only pcs5__bc_switch_quantities inverter_voltage_a_phase_overvoltage_fault_flag 0 Use → row 6
29971 BOOL 1 read only pcs5__pcs inverter_voltage_phase_a_overvoltage_fault_flag 0 Use → row 6
29972 BOOL 1 read only pcs5__bc_switch_quantities inverter_voltage_b_phase_overvoltage_fault_flag 0 Use → row 6
29973 BOOL 1 read only pcs5__pcs inverter_voltage_phase_b_overvoltage_fault_flag 0 Use → row 6
29974 BOOL 1 read only pcs5__bc_switch_quantities inverter_voltage_c_phase_overvoltage_fault_flag 0 Use → row 6
29975 BOOL 1 read only pcs5__pcs inverter_voltage_phase_c_overvoltage_fault_flag 0 Use → row 6
29976 BOOL 1 read only pcs5__pcs grid_islanding_fault_flag 0 Use → row 6
29977 BOOL 1 read only pcs5__pcs system_resonance_fault_flag 0 Use → row 6
29978 BOOL 1 read only pcs5__bc_switch_quantities software_overvoltage_overcurrent_flag 0 Use → row 6
29979 BOOL 1 read only pcs5__pcs software_overvoltage_and_overcurrent_flag 0 Use → row 6
29980 BOOL 1 read only pcs5__bc_switch_quantities high_voltage_ride_through_timeout_fault_flag 0 Use → row 6
29981 BOOL 1 read only pcs5__pcs high_voltage_ride_through_timeout_fault_flag 0 Use → row 6
29982 BOOL 1 read only pcs5__bc_switch_quantities inverter_voltage_a_phase_undervoltage_fault_flag 0 Use → row 6
29983 BOOL 1 read only pcs5__pcs inverter_voltage_phase_a_undervoltage_fault_flag 0 Use → row 6
29984 BOOL 1 read only pcs5__bc_switch_quantities inverter_voltage_b_phase_undervoltage_fault_flag 0 Use → row 6
29985 BOOL 1 read only pcs5__pcs inverter_voltage_phase_b_undervoltage_fault_flag 0 Use → row 6
29986 BOOL 1 read only pcs5__bc_switch_quantities inverter_voltage_c_phase_undervoltage_fault_flag 0 Use → row 6
29987 BOOL 1 read only pcs5__pcs inverter_voltage_phase_c_undervoltage_fault_flag 0 Use → row 6
29988 BOOL 1 read only pcs5__pcs off_grid_no_synchronization_signal_fault_flag 0 Use → row 6
29989 BOOL 1 read only pcs5__pcs off_grid_short_circuit_fault_flag 0 Use → row 6
29990 BOOL 1 read only pcs5__bc_switch_quantities low_voltage_ride_through_timeout_fault_flag 0 Use → row 6
29991 BOOL 1 read only pcs5__pcs low_voltage_ride_through_timeout_fault_flag 0 Use → row 6
29992 FLOAT32 2 read only pcs5__bc_battery_cluster battery_temperature_c 25 Use → row 6
29994 INT16 1 read only pcs5__bc_battery_cluster dc_current_a 0 Use → row 6
29995 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_1_mv 3300 Use → row 6
29996 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_2_mv 3301 Use → row 6
29997 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_3_mv 3302 Use → row 6
29998 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_4_mv 3303 Use → row 6
29999 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_5_mv 3304 Use → row 6
30000 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_6_mv 3305 Use → row 6
30001 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_7_mv 3306 Use → row 6
30002 UINT16 1 read only pcs5__bc_battery_cluster cell_voltage_8_mv 3307 Use → row 6
30003 UINT16 1 read only pcs5__bc_battery_cluster operating_status 0 Use → row 6
30004 UINT16 1 read only pcs5__bc_battery_cluster cluster_voltage_v 0 Use → row 6
30005 INT16 1 read only pcs5__bc_battery_cluster cluster_current_a 0 Use → row 6
30006 UINT16 1 read only pcs5__bc_battery_cluster maximum_allowable_charging_power_kw 0 Use → row 6
30007 UINT16 1 read only pcs5__bc_battery_cluster maximum_allowable_discharging_power_kw 0 Use → row 6
30008 UINT16 1 read only pcs5__bc_battery_cluster soc_state_of_charge_item 0 Use → row 6
30009 UINT16 1 read only pcs5__bc_battery_cluster soh_state_of_health_item 0 Use → row 6
30010 UINT16 1 read only pcs5__bc_battery_cluster maximum_cell_voltage_mv 0 Use → row 6
30011 UINT16 1 read only pcs5__bc_battery_cluster maximum_cell_voltage_module_number 0 Use → row 6
30012 UINT16 1 read only pcs5__bc_battery_cluster maximum_cell_voltage_cell_number 0 Use → row 6
30013 UINT16 1 read only pcs5__bc_battery_cluster minimum_cell_voltage_mv 0 Use → row 6
30014 UINT16 1 read only pcs5__bc_battery_cluster minimum_cell_voltage_module_number 0 Use → row 6
30015 UINT16 1 read only pcs5__bc_battery_cluster minimum_cell_voltage_cell_number 0 Use → row 6
30016 INT16 1 read only pcs5__bc_battery_cluster maximum_cell_temperature_c 0 Use → row 6
30017 UINT16 1 read only pcs5__bc_battery_cluster maximum_cell_temperature_module_number 0 Use → row 6
30018 UINT16 1 read only pcs5__bc_battery_cluster maximum_cell_temperature_cell_number 0 Use → row 6
30019 INT16 1 read only pcs5__bc_battery_cluster minimum_cell_temperature_c 0 Use → row 6
30020 UINT16 1 read only pcs5__bc_battery_cluster minimum_cell_temperature_module_number 0 Use → row 6
30021 UINT16 1 read only pcs5__bc_battery_cluster minimum_cell_temperature_cell_number 0 Use → row 6
30022 UINT32 2 read only pcs5__bc_battery_cluster cumulative_charging_energy_kwh 0 Use → row 6
30024 UINT32 2 read only pcs5__bc_battery_cluster cumulative_discharging_energy_kwh 0 Use → row 6
30026 UINT16 1 read only pcs5__bc_battery_cluster main_positive_relay_status 1 Use → row 6
30027 UINT16 1 read only pcs5__bc_battery_cluster main_negative_relay_status 1 Use → row 6
30028 UINT16 1 read only pcs5__bc_battery_cluster pre_charge_relay_status 1 Use → row 6
30029 UINT16 1 read only pcs5__bc_battery_cluster communication_status 1 Use → row 6
30030 UINT16 1 read only pcs5__bc_battery_cluster bms_level_1_alarm 0 Use → row 6
30031 UINT16 1 read only pcs5__bc_battery_cluster bms_level_2_alarm 0 Use → row 6
30032 UINT16 1 read only pcs5__bc_battery_cluster bms_level_3_alarm 0 Use → row 6
30033 INT16 1 read/write pcs5__control__remote_control active_power_set_kw 0 Use → row 6
30034 UINT16 1 read only pcs5__air_condition unit_operating_status 1 Use → row 6
30035 UINT16 1 read only pcs5__air_condition air_conditioner_alarm 0 Use → row 6
30036 UINT16 1 read only pcs5__air_condition air_conditioner_fault 0 Use → row 6
30037 UINT16 1 read only pcs5__air_condition communication_status 1 Use → row 6
30038 UINT16 1 read only pcs5__fire_detector temperature_c 25 Use → row 6
30039 UINT16 1 read only pcs5__fire_detector temperature_alarm 0 Use → row 6
30040 UINT16 1 read only pcs5__fire_detector gas_alarm 0 Use → row 6
30041 UINT16 1 read only pcs5__fire_detector communication_status 1 Use → row 6
30042 INT16 1 read only pcs5__pcs a_phase_output_current_a 0 Use → row 6
30043 INT16 1 read only pcs5__pcs b_phase_output_current_a 0 Use → row 6
30044 INT16 1 read only pcs5__pcs c_phase_output_current_a 0 Use → row 6
30045 INT16 1 read only pcs5__pcs a_phase_voltage_v 0 Use → row 6
30046 INT16 1 read only pcs5__pcs b_phase_voltage_v 0 Use → row 6
30047 INT16 1 read only pcs5__pcs c_phase_voltage_v 0 Use → row 6
30048 INT16 1 read only pcs5__pcs three_phase_total_active_power_kwh 0 Use → row 6
30049 INT16 1 read only pcs5__pcs three_phase_total_reactive_power_kvar 0 Use → row 6
30050 INT16 1 read only pcs5__pcs three_phase_total_apparent_power_kvar 0 Use → row 6
30051 UINT32 2 read only pcs5__pcs cumulative_discharging_energy_kwh 0 Use → row 6
30053 UINT32 2 read only pcs5__pcs cumulative_charging_energy_kwh 0 Use → row 6
30055 INT16 1 read only pcs5__pcs module_current_maximum_temperature_c 0 Use → row 6
30056 INT16 1 read only pcs5__pcs dc_power_kw 0 Use → row 6
30057 INT16 1 read only pcs5__pcs dc_voltage_v 0 Use → row 6
30058 INT16 1 read only pcs5__pcs dc_current_a 0 Use → row 6
← Previous Page 48 of 75 Next →